Nec chapter 9 table 9. Z = impedance of the conductor per 1000 ft.

February 28, 2021. 6. Remember that (ºF - 32) / 1. Mar 12, 2023 · Here is an explanation of how to use Chapter 9, Table 9 in the NEC. Bob Anchorite said: On table 8, page 70-625 of the 2002 NEC there is a listing of circular mils. Proper Sizing of Conduits and Raceways. Apr 6, 2021 · Table 9 Alternating-Current Resistance and Reactance for 600-Volt Cables, 3-Phase, 60 Hz, 75°C (167°F) — Three Single Conductors in Conduit. 081/. (5) For cables not included in the tables in Chapter 9, such as multiconductor cables, the actual dimensions of the cables shall be used in conduit fill calculations. NEC Table 310. 31 2. Table 1 Percent of Cross Section of Conduit and Tubing for Conductors and Cables. Why Table 2 and Table 4 are helpful. NFPA 731 Section 4. 08 2. Diam (in) Area (in²) Table 310. 2 NEC Chapter 9, Table 4, Dimensions and Percent Area of Conduit and Tubing (Areas of Conduit or Tubing for the Combinations of Wires Permitted in Table 1 Terms in this set (22) Table 1. 50 1500 1750 2000 Notes: mm2 0. Raceways must be large enough to permit the installation and removal of conductors without Table 2. Using conductors having coated strands , different stranding type, and, especially, other temperatures changes the resistance. Table 5. Chapter 9, Table 8 calculations are based on conductors at 75ºC. Mark Lamendola. ) 31% raceway area for 2 conductors C. ) 40% raceway area for over 2 conductors 1. In this video we’ll show you how t 0. (6) For combinations of conductors of different sizes, use actual dimensions or Table 5 and Table 5A for dimen‐ sions of conductors and Table 4 for the applicable conduit or tubing dimensions. Chapter 9 Percent of Cross Section of Conduit and Tubing for Conductors and Cables. 7. ) Raceway Sizing There are three options for sizing raceways according to 2017 PEC Table 10. Percent of Cross Section of Conduit and Tubing for Conductors and Cables. Table 4. , Electrical conductors installed in rigid metal conduit encased in concrete are considered ? . 9 for copper, and 21. 4- Approximate Mathematical Method, 5 Conduit Sizing, NEC Chapter 9, Tables 4 and 5. Total Area. LINE QTY SIZE TYPE AREA TOTAL AREA; 1 NEC 2020 Compliant. 15(B)(16) Conductor Ampacities: Ampacities of Insulated Conductors with Not More Than Three Current-Carrying Conductors in Raceway, Cable, or Earth (Directly Buried) Chapter 9 Table 1: Conduit Cross-Section Percentage for Conductors: Percent of Cross Section of Conduit and Tubing for Conductors and Cables NEC Chapter 9 Table 4. What is the voltage drop of two 12 AWG THHN conductors that supply a 16A, 120V load located 100 feet from the power supply? (a) 3. 8V. Free NEC 2005: Chapter 9 Table 8. For example, the City of LA wants you to use Chapter 9, Table 8 for #2 AWG or smaller, and Chapter 9, Table 9 for larger than #2 AWG. where: Vd = voltage drop. The preparation of PEC1 2017 started in 2016 and was completed in 2017, a more than one-year effort. Study with Quizlet and memorize flashcards containing terms like Table 1, Table 2, Table 4 and more. , Which of the following would not be included in NEC Chapter 9, Table 8? and more. Article 358 - Electrical Metallic Tubing (EMT) Metric Designator Trade Size Nominal Internal Diameter Total Area 100% 60% 1 Wire 53% 2 Wires 31% NEC Chapter 9 Tables - Free download as PDF File (. The NEC sets standards for the percent of volume that can safely be put into conduit. Website by 18 3. 261 5. 93 ohms for the same piece of wire. In the NEC ®, there are two main locations (near the back Flashcards NEC Chapter 9: Tables and the Informative Annexes | Quizlet. So I would use table 9. S. 901. 08 3. 15(B)(16), I know which wire I need to use. 1. Table 1 sets the actual percentage fill rule, Table 4 gives you the area of the raceways, and Table 5 gives you the area of the conductors. , If a conductor has a low resistance, it _____. Compact copper and AL building wire nominal dimensions and Areas. Cable properties DC NEC 2005 table 8 chapter 9 Study with Quizlet and memorize flashcards containing terms like A circular mil is a circle with a circumference of one mil. For conductors not included in Chapter 9, such as multiconductor cables, the actual dimensions shall be used. 6 AWG, Type UF copper cable is _____. That’s pretty much the meat and cheese of CHAPTER 9 Direct-Current Resistance at 750C (167 OF) Copper Table 8 Conductor Properties TABLES Conductors Overall Diameter Size (AWG kcmil) 18 18 16 16 14 12 12 10 10 1/0 2/0 3/0 4/0 2. Dimensions of Insulated Conductors and Fixture Wires: SIZE: WIRE TYPE: AWG or kcmil The diagram shows conductors/cables lying in a conduit in sets of one, two, three and four. 0139 Mar 6, 2015 · Vd = ( 1. 16 formerly Table 310. Chapter 8 stands alone unless it specifically references an earlier requirement. In the NEC ®, there are two main locations (near the back 5. You aren’t required to use the Chapter 9 tables of the National Electrical Code (NEC), but they can be surprisingly useful. 0145 16 3. When calculating the number of 10 AWG conductors that may be installed in a raceway, when the calculation results in a decimal of ? or greater, the calculated number can be NEC Chapter 9 Tables. Chapter 5–7 supplements or modifies the information in Chaps. Chapter 9 Tables NEC 2014: Chapter 9 Table 1. chapter 9 table 1. 18 3. 20]. Mar 27, 2017 · My question is that after I calculate ampacity using Table310. txt) or read online for free. 573. 3. Chapter 9 Table 4 — Conduit Dimensions. 10 AWG wiring has, Using NEC table 310. 15 26. 16 ohm * 150/1000 * 100A = 2. 10 0. 157V. 6V (d) 12. 1 Understanding the NEC, Chapter 9 Tables Table 1—Conductor Percent Fill The maximum percentage of allowable conductor fill is listed in Chapter 9, Table 1. Table 9 Alternating-Current Resistance and Reactance for 600-Volt Cables, 3-Phase, 60 Hz, 75°C (167°F) — Three Single Conductors in Conduit. April 6, 2021. NEC 1999: Chapter 9 Table 4. Size (AWG or kcmil) XL (Reactance) for All Wires. AWG / KCMIL. site. ) Oct 15, 2019 · The formulas included here are based on conductor DC resistance values provided in Chapter 9 Table 8 of the NEC, and are viewed as generally acceptable for voltage drop calculations. 31 3. The Electrical Calc Elite is designed to solve many of your common code-based electrical When three conductors are pulled into a raceway, they may flatten out creating a condition where the conductors could jam. (4) Conduit nipples are permitted to be filled up to 60%. Ohms to Neutral per Kilometer. Click the icons below to get our NEC ® compliant Electrical Calc Elite or Electric Toolkit for Android and iOS. Use the following formula (from the NEC, Table 8-Notes) to determine the resistance of 1,000 feet of #12 wire at 105°C. 819. To determine how much wire you can run in a given raceway: Find the raceway type and size you're running, in Table 4 of Chapter 9. 1 [ or 2017 NEC Chapter 9 Table 1 ], based on cross-sectional areas: A. in. And I'd put it in a spreadsheet to automate the process, or use one of the online calculators like Dennis suggested. Mar 20, 2014. They performed the following: Voltage drop (line to neutral) = 0. Table 8 is based on 75°C/167°F, and provides a k-factor constant of 12. Dimensions and Percent Area of Conduit and Tubing (See Chapter 9 Table 1 for allowed use of conduit area) Electrical Metallic Tubing. Dimensions of Insulated Conductors just that. 001, and then square the result to get circlular mils. 8 — Number of The Same Size Conductors in Trade Size of Conduit or Tubing Liquidtight Flexible Metal Conduit (LFMC) Conductor Types THHN, THWN, THWN-2 (Based on Table 1, Chapter 9) 100% 80% Mar 24, 2020 · This calculation will explain how to find the distance of a conductor. New Temperature in ºC, "T 2" Jan 28, 2022 · For this reason, the National Electrical Code (NIC) is revised every three years, with the latest edition being released as NFPA 70-2017 – National Electrical Code, 2017 edition. Some jurisdictions have a set policy regarding which table you should use for voltage drop calculations. NEC Chapter 9 Table 4: Dimensions and Percent Area of Conduit and Tubing: EMT (Electrical Metallic Tubing) NEC Table 310. 16. Table 2. NEC 2014: Chapter 9 Table 8. Stranding. 14 AWG THW conductor = 0. (see NEC chapter 9 table 8 or 9) I = load current in amperes. Radius of Conduit and Tubing Bends. Table 9 Alternating-Current Resistance and Reactance for 600-Volt Cables, 3-Phase, 60 Hz, 75°C (167°F) - Three Single Conductors in Conduit. Back to Index of NEC Tables. 22. Wires 31% Metric Designator Trade Size mm. 3808. 4. THHN / THWN. 0106. 148 11. EMT with a one-shot bender (manual) or a full shoe (machine), what is the (5) For conductors not included in Chapter 9, such as multi‐ conductor cables and optical fiber cables, the actual dimensions shall be used. NEC Chapter 9 is used for combinations of conductors of different sizes or insulation types installed in the same conduit or tubing. Table 5A. , Using NEC Table 310. Table 5 Continued Type Size (AWG or Chapter 9 Tables. 73 x Z x I x L) / 1000 ---> for three phase system. Raceways, conduits and tubing are not always used with security system wiring but if they are, the raceway conduit or tubing must be sized according to the NEC ®. Table 4 Dimensions and Percent Area of Conduit and Tubing (Areas of Conduit or Tubing for the Combinations of Wires Permitted in Table 1, Chapter 9) Article 358 — Electrical Metallic Tubing (EMT) Nominal Internal Diameter Total Area 100% 60%. In the NEC ®, there are two main locations (near the back Feb 28, 2021 · Chapter 9 Tables. It is titled “ Table 9 Alternating-Current Resistance and Reactance for 600-Volt Cables, 3-Phase, 60 Hz, 75 Table 1. _____. The maximum is trade size 4 for IMC and trade size 6 for RMC [Sec. It’s based on common conditions where the length of the conductor and number of raceway bends are within reasonable limits [Chapter 9, Table 1, Note 1]. Using the NEC code book. Trade Size. 31(F) and 690. Video covering the NEC Chapter 9 Tables as well as Annex C. #6. Where conduit or tubing nipples having a maximum length not to exceed 24 inches are installed between boxes, cabinets, and similar enclosures, the nipples shall be permitted to be filled to 60% of their total cross-sectional area, and NEC Chapter 9 Table 5. and more. Study with Quizlet and memorize flashcards containing terms like A rigid fishing tool used for long conduit runs is known as a _____. However, that table 9 on NEC says Three-Single-Conductors in Conduit. May 24, 2011 · Note 6 of Table 1 provides you with instructions when working with combinations of conductors of different sizes, and refers you to Table 5 of Chapter 9 for the approximate cross-sectional area of each individual conductor. That doesn’t seem correct to me. Electrical reactance is a measure of the opposition to current flow from inductance or capacitance. The Electrical Calc Elite is designed to solve many of your common code-based electrical calculations like wire sizes, voltage drop, conduit sizing, etc. pdf - Free download as PDF File (. Table 1 gives permissible fill percentages for conductors in conduit and tubing. Tables at the end of Chapter 9 help when working with Art. According to NEC Table 8, Chapter 9, Conductor Properties; What is the Direct-Current Resistance at 75°C (167°F) for Copper that is Coated in Ohm/kFT (Ohms per 1,000 ft. 367 13. Z = impedance of the conductor per 1000 ft. Learn how to calculate voltage drop in electrical circuits and why it is important for equipment efficiency and safety. Jun 5, 2023 · Taking a look at NEC Chapter 9 Table 9 calculation example, they are using a feeder with 100A continuous load, 240V source, 3 phase with a circuit length of 150 feet. Mar 20, 2014 · Electrical Engineer. Consider Table 2. CH15_Hickey 11/15/01 11:27 AM Page 15. The use of Chapter 9, Table 1 for conduit fill allows the use of which additional tables in the notes to Table 1? Click the card to flip. Use Table 9 to determine electrical reactance values. Class 2 and Class 3 Alternating Current Power Source Limitations. I was taught that to find circular mils one takes the diameter in inches and divide that by . It started with NEC 2014 as the basis, but in the end, adopted NEC 2017 which became available September 2016. Conductor Properties. Terms in this set (21) The use of Chapter 9, Table 1 for conduit fill allows the use of which additional tables in the notes to Table 1? Tables 4, 5, 5A, and 8. NEC 2008: Chapter 9 Table 8. 1–7. Ohms to Neutral per 1000 Feet. Improve your grades and reach your goals with Free NEC 2014: Chapter 9 Table 5. Fine stranded cable has already been used with photovoltaic systems, so requirements similar to section 110. April 19, 2021. 001 = 81. The National Electrical Code chapter 9 provides conductor The NEC Chapter 9, Table 8, gives 1. Looking back to the diagram, this is due to the two conductors or cables forming an oval, rather than a circle. Dimensions and Percent Area of Conduit and Tubing (Areas of Conduit or Tubing for the Combinations of Wires Permitted in Table 1, Chapter 9) Table 5. Chapter 9 Tables. Thread starter Tainted; Start date Jan 2, 2024; Tainted Senior Member. Chapter 9 contains major tables and are used when referenced as applicable in the Code. For example, Table C. 1 / 8. Mar 4, 2018 · Stuck on NEC Chapter 9, table 8. 5. 53%. Study with Quizlet and memorize flashcards containing terms like According to NEC chapter 9, Table 8, No. 1: Table 1 is based on common conditions of proper cabling and alignment of conductors where the length of the pull and the number of bends are within reasonable limits. Apr 6, 2021 · The resistance is calculated in accordance with National Bureau of Standards Handbook 100, dated 1966, and Handbook 109, dated 1972. 31 1. The appendices complete the Code. Overall. Jun 1, 2004 · R = Conductor resistance, Chapter 9, Table 8 for DC or Chapter 9, Table 9 for AC; Let's do a sample calculation using the Ohm's Law method. 0172 RHH, RHW, CHAPTER 9 TABLES 70–716 NATIONAL ELECTRICAL CODE 2011 Edition. 4V. NEC 2011 Chapter 9, table 1, shows that the maximum conduit allowance. The Electric Toolkit provides some basic Table 9 provides AC resistance and reactance information for both copper and aluminum conductors based on conductor type and size, and the type of conduit used for the raceway. If you would like to see how the values change when the temperature changes, enter a new temperature value in the input box below. Informational Note No. - NEC 2014, Chapter 9 – “Tables”, Table 9 – “AC Resistance & Reactance” Table 9 - AC Resistance/Reactance Note that the actual table states “Uncoated Copper” Chapter 9 Tables, Note 9. The new language in this section refers to that table, making its provisions enforceable by the AHJ. The difference in resistance is due to a temperature difference. 2952. A check of Table 5 reveals the following information: 12 AWG THHN conductor = 0. 732 = 4. Location New York Occupation Engineer (PE) Jan 2, 2024 #1 Apr 19, 2021 · Chapter 9 of the NEC — Part 7. Click Subscribe above. Table 8 shows straight resistance and table 9 shows "AC resistance", which is actually impedance at 60Hz. 1: Table 1 is based on common condi‐ tions of proper cabling and alignment of conductors where the length of the pull and Jan 20, 2017 · No. 823 1. The below chart is from Table 1 in Chapter 9 of the National Electric Code. Dimensions and Percent Area of Conduit and Tubing (See Chapter 9 Table 1 for allowed use of conduit area) Click the icons below to get our NEC ® compliant Electrical Calc Elite or Electric Toolkit for Android and iOS. 344. Conduit Fill Tables – NEC Table C Conductor Size – Awg / Kcmil – XHHW SIZE 14 12 10 8 6 4 3 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 750 Apr 14, 2023 · The minimum trade size is 1/2-in. Jan 29, 2020 · Djelite said: Ok that’s still not chapter 9 table 1. 759 0. , According to the NEC®, the minimum free conductor length required for making splices is _____. Dimensions of Insulated Conductors and Fixture Wires. In the article Calculations of Voltage Drop - Part One I pointed out that there are eight methods of calculating voltage drop as follows: 1-Ohm's Law Method, 2-European Method, 3-U. 20, Sec. Apr 26, 2020 · RACEWAY SIZES (CONDUIT AND TUBING) 1. The geometric mean distance (equivalent conductor spacing) impacts the impedance of the conductors; this is the case with busways also. #2. 342. . Also, Table 9 (and my spreadsheet) allows you to consider the type of conduit. 15(C)(1) adjustment Jan 16, 2012 · Table 8 is a DC resistance, and it looks like the value for #12 is slightly lower than the AC resistance given in Table 9. Dimensions and Percent Area of Conduit and Tubing. 74 in the 2008 NEC. Dec 9, 2021 · To start out, the NEC is layed out in a specific way. 6 AWG, type UF copper cable is, If a Conductor has a low resistance it and more. 823 0. Apr 21, 2011 · Consequently, the 2011 NEC stresses the need to use specific terminations for fine-stranded conductors and cables. 15(B)(3)(a), then Table 310. Mar 27, 2010 · NEC Chapter 9 said: These resistance values are valid only for the parameters given. This section refers the user to Chapter 9, Table 1. 1000 = constant to compensate with "per 1000 ft" in impedance value. 31 5. There are 9 Chapters to the book as well as a section of definitions in the front and some helpful informational Annexes in the back. 8 = ºC. Where conduit or tubing nipples having a maximum length not to exceed 24 inches are installed between boxes, cabinets, and similar enclosures, the nipples shall be permitted to be filled to 60% of their total cross-sectional area, and 310. pdf) or read online for free. NEC Chapter 9 Table 4. In the NEC ®, there are two main locations (near the back Mar 23, 2022 · Because of this, Chapter 9 - Tables before is now Chapter 10. Study with Quizlet and memorize flashcards containing terms like According to NEC Chapter 9, Table 8, No. Chapter 9 of the National Electrical Code (NEC) ends with a series of related tables: 11 (A). Click the card to flip 👆. “I” = Amperes: The load in amperes at 100 percent, not 125 percent for motors or continuous loads. 4V * 1. For my project, I need to do calculations for various temperatures. To find line-to-line voltage drop they took 2. EMT (Electrical Metallic Tubing) ENT (Electrical Nonmetallic Tubing) FMC (Flexible Metal Conduit) IMC (Intermediate Metal Conduit) LFNC-B (Liquidtight Flexible Nonmetallic Conduit type B) LFNC-A (Liquidtight Flexible Nonmetallic Conduit type A) LFMC Conduit fill requires calculation. For combinations of conductors of different sizes, use Table 5 and Table 5A for dimensions of conductors and Table 4 for the applicable conduit or tubing dimensions. As you can see two conductors is the smallest maximum fill. 1 Wire. Chapman Electric offers a selection of pipe and conduit to meet your electrical or underground project needs. for both IMC and RMC. Note (4). Conduit Size Calculator. Since my length of wire is long, I am considering there is voltage drop. 14 can also be found in sections 690. , Chapters of the NEC are broad in scope and are subdivided into different ? to address the chapter scope. In the past, this involved determining the circular mils for various conductors. Table 1 Percent of Cross Section of Conduit and Tubing for Conductors and Cables Number of Conductors and/or Cables Cross-Sectional Area (%) 1 53 2 31 Over 2 40 Informational Note No. Sep 10, 2006 · Sep 10, 2006. Nec chapter 9 table 8 conductor properties. Table9_1 - Free download as PDF File (. Figure 5–1 NEC 2014: Chapter 9 Table 4. 454 0. NFPA 70-2017, like its predecessors, is the National Electrical Code (NEC) of the United States, striving for the ultimate goal of facilitating the safe installation NEC Chapter 9 Table 4. 2, 2021. Fill requirements for rigid metal conduit are addressed in Section 344. If you are bending 1-in. Get a hint. Code Change Summary: Chapter 9, Note 9 was expanded to clarify the rules on calculating cables in a conduit or raceway. 367 8. 16, what is the Ampacity of a # 6 AWG Copper THHN (194°F) conductor. 760. ) for a size #10 AWG SOLID; 1. I am using VD=L*R*I/1000 where R values are from Table9 in NEC. 30 21. Understanding the layout will help you get a birds-eye view of the entire “realm” that this map is covering. 136 9. Table 5 Continued Type Size (AWG or The "Q" adjustment factor is determined by dividing alternating current resistance as listed in NEC Chapter 9, Table 9, by the direct current resistance as listed in Chapter 9, Table 8. 67 Notes to Tables in Chapter 9 of the NEC: (3) Equipment grounding conductors shall be included in conduit fill calculations. 12 (2) requires raceways to be sized properly in accordance with the NEC ®. I am doing voltage drop calculations. 1 Section 15 NEC Chapter 9 Tables and Annexes B and C 15. 11 (B). NEC Chapter 9 Table 5. 1 NEC Chapter 9, Table 1, Percent of Cross Section of Conduit and Tubing for Conductors 15. However, NEC table displays only the readings for 75 degrees. Percent of Cross section of conduit and Tubing for conductors and cables. 355 0. L = length in feet. , A mil foot is one foot in length with a diameter of one mil. 1. DC Resistance at 75C (167F) (AWG or kcmil) Area. 4V (c) 9. For complete systems, the number of conductors cannot exceed the percentage fill in Chapter 9, Table 1. Conduit Wire Fill Charts & Tables. The math is straightforward: I = 16A chapter 9 table 1. Chapters 1–4 generally applies to all electrical installations. Calculate to two decimal places. XHH / XHHW. Wire 53%. Insulation Type. In table 8 it shows that #12 awg has a diameter in inches of . , According to NEC Chapter 9, Table 8, solid wire is available up to size No. 2 for aluminum conductors. for impedances 5046. 2020 Code Language: Chapter 9 Percent of Cross Section of Conduit and Tubing for Conductors and Cables. Jan 2, 2024 · NEC Chapter 9 Table 9. Apr 6, 2021 · Chapter 9 of the NEC — Part 6. 081 . Reactance is in there. Inductive and capacitive components store energy. Alternating-Current Resistance for Alternating-Current. Table C. 75A. The percentage to use for conduit fill when installing one cable assembly with five conductors in the cable assembly is ? . table 8 DC NEC 2005 - Free download as PDF File (. Table 10 in Chapter 9 makes its first appearance with the 2011 revision. 486A-B is reproduced in chapter 9 table 10 of the 2011 NEC so this requirement can be applied in the field (see table “Conductor Stranding” located on page 2). Internal Diameter. 0133 sq in. There are many tables in NEC Annex C, each of which is for a different raceway type. Tables 4, 5, 5A, and 8. 0. 10 AWG wiring has _____. 2V (b) 6. 16, the ampacity of a No. TABLES. 100%. Quizlet has study tools to help you learn anything. This document provides tables related to conduit and tubing dimensions from Chapter 9 of the National Electrical Code (NEC). 261 8. Size. Mathematical and electrical tools, calculators, and Chapter 9 Tables. Conductors of different size are calculated with table 5 chapter 9. 6. NEC Chapter 9 Table 1: Percent of Cross Section of Conduit and Tubing for Conductors and Cables Conduit. Chapter 9, Note 9 previously stated that multiconductor cable, optical fiber cable, or flexible cord of two or more conductors is treated as a single conductor for calculating the percentage of Study with Quizlet and memorize flashcards containing terms like Tables located in Chapter 9 apply only where ? . 50 300 350 400 500 600 700 750 800 900 1000 12. Conductors. I am trying to do the calculations from R2 = R1 [1 + α (T2 − 75)]. THW / THHW. 15(B)(16), the ampacity of a No. Notes to Tables. pdf), Text File (. According to NEC Table 310. Method, which is divided into: Circular-mils method, chapter table method (9). Find out the NEC recommendations and requirements for voltage drop based on Fine Print Notes and rules. Feb. There are questions on the electrical journeyman's/ masters test that will pertain to thi The "Q" adjustment factor is determined by dividing alternating current resistance as listed in NEC Chapter 9, Table 9, by the direct current resistance as listed in Chapter 9, Table 8. This reference to Table 1 in Chapter 9 allows for the use 25A. Table 2 provides minimum bend radii for Feb 2, 2021 · Chapter 9 of the NEC — Part 2. 1 in Annex C provides the maximum number of conductors or fixture wires permitted in electrical metallic For instance, NEC Chapter 9 tables would not be appropriate for medium-voltage voltage drop calcs, as higher voltage circuits require thicker insulation, which increases conductor spacing. 0348. Size (AWG or kcmil) Ohms to Neutral per Kilometer Ohms to Neutral per 1000 Feet. 26 ohm/kFT. The table specifies separately impedance, reactance, and resistance. You still have to use Table 1 along with Tables 4 and 5. Fortunately, the NEC now provides tables to reduce the amount of calculation in the field. ) 53% raceway area for 1 conductor (a multiconductor cable is treated as a single conductor [Note 9]) B. sy un re hm kh ts ir ne ei qe